Self Contained Open Circuit Breathing Apparatus
Self Contained Open Circuit Breathing Apparatus

Self Contained Open Circuit Breathing Apparatus

Self Contained Open Circuit Breathing Apparatus Specification

  • Noise Level
  • <80 dB (Operational)
  • Air Discharge
  • Positive Pressure via Demand Valve
  • Condition
  • New
  • Material
  • High Strength Composite/Aluminum Cylinder, Flame Resistant Harness
  • Power Source
  • Compressed Air Cylinder
  • Dimensions
  • Approx. 600 x 300 x 200 mm (without cylinder)
  • Lubrication Type
  • Oil-Free/Not Required
  • Configuration
  • Single Cylinder, Harness & Mask
  • Mute
  • No
  • Air Flow Capacity
  • 40-60 L/min
  • Driven Method
  • Manual Use (Self-contained unit)
  • Working Presssure
  • 200/300 Bar
  • Motor
  • Not Applicable (Pneumatic)
  • Color
  • Hi-Viz Yellow/Black
  • Carrying Case
  • Optional, Heavy Duty Polymer
  • Face Mask Type
  • Full Face, Wide View, Anti-Scratch Visor
  • Usage Application
  • Firefighting, Rescue, Emergency Response
  • Valve Type
  • Automatic Positive Pressure Demand Valve
  • Head Harness
  • 5-Point Adjustable Rubber
  • Cylinder Material
  • Composite Wrapped Aluminum
  • Temperature Range
  • -30°C to +60°C
  • Backplate Material
  • Corrosion Resistant Polymer
  • Cylinder Capacity
  • 6.8 L / 300 Bar
  • Warning Device
  • Whistle at 60 ± 5 bar remaining air pressure
  • Harness Type
  • Adjustable, Padded, Flame Retardant
  • Weight (without cylinder)
  • Approx. 2.5 kg
  • Duration
  • Approximately 45 to 60 Minutes (at 40-60 L/min draw)
 
 

About Self Contained Open Circuit Breathing Apparatus

Usage/Application Hospital
Brand Mediline
Audio Alarm System 8 Minutes
Duration of Working 30 Minutes
Capacity of Cylinder 800 L
Body Material SS
Country of Origin Made in India

Engaged in offering range of Self Contained Open Circuit Breathing Apparatus. Known for their high durability these Breathing Apparatus are majorly used in emergencies. We offer these at competitive market rates.

Reliable Air Supply for Critical Applications

Engineered for firefighting, emergency response, and rescue missions, this self-contained breathing apparatus ensures dependable breathable air in hazardous environments. The 6.8 L, 300 Bar composite cylinder provides up to 60 minutes of use, helping users operate safely and efficiently during urgent operations.


Enhanced Comfort and Safety Features

With an adjustable, padded, flame-retardant harness and a lightweight ergonomic backplate, users experience comfort even during prolonged wear. The anti-scratch, full-face mask delivers a wide field of view while keeping the wearer's vision clear and unobstructed during demanding activities.


Built to Withstand Extreme Conditions

This apparatus operates reliably between -30C and +60C. The corrosion-resistant polymer backplate and high-visibility yellow/black color enhance durability and user safety, while the warning whistle ensures timely cylinder change in critical moments.

FAQ's of Self Contained Open Circuit Breathing Apparatus:


Q: How does the automatic positive pressure demand valve system work in this breathing apparatus?

A: The automatic positive pressure demand valve delivers air only when the user inhales, maintaining a positive pressure within the face mask. This prevents contaminated external air from entering, ensuring the user breathes only clean, compressed air from the cylinder.

Q: What is the process for donning and adjusting the harness for optimal fit?

A: To achieve a secure fit, first lift the harness over the shoulders, buckle the padded harness, and tighten the adjustable straps. Adjust the 5-point rubber head harness on the face mask to ensure a snug, air-tight seal without discomfort, optimizing comfort and safety.

Q: When should the warning whistle be expected to sound, and what does it indicate?

A: The built-in whistle activates automatically when the remaining air pressure in the cylinder drops to 60 5 bar. This alerts the wearer to exit the hazardous area promptly or prepare to change cylinders, ensuring safety during use.

Q: Where is this breathing apparatus typically used?

A: This apparatus is primarily deployed in firefighting, rescue missions, and emergency response operations, particularly where hazardous atmospheres or smoke are present, providing reliable respiratory protection for professionals in India and similar environments.

Q: What are the primary benefits of using a full-face, anti-scratch visor mask?

A: The full-face mask features a wide view and anti-scratch visor, offering users better visibility and protection from debris, contaminants, and impacts. This ensures clear vision and robust facial protection in hazardous conditions.

Q: How can the apparatus be maintained for long-term reliability?

A: Regularly inspect all seals, straps, and the face mask for wear or damage. After use, clean the mask and harness per manufacturer guidelines and store the device in its optional heavy-duty polymer case in a cool, dry place to ensure longevity.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Plant Medical Air Vacuum System Category

Light Weight and Portable Mediline Oxygen Kit

Light Weight and Portable Mediline Oxygen Kit

Condition : New

Noise Level : < 45 dB

Configuration : Complete readytouse kit

Motor : Brushless DC

Dimensions : 40 x 20 x 20 cm

Air Discharge : Adjustable from 1 to 10 LPM

Vertical Receiver Tank

Vertical Receiver Tank

Condition : New

Noise Level : Silent Operation

Configuration : Vertical

Motor : Not Included

Dimensions : Dia 500mm x Height 2000mm (Approx)

Air Discharge : Bottom Outlet

Lightweight Self Contained Open Circuit Breathing Apparatus

Lightweight Self Contained Open Circuit Breathing Apparatus

Condition : New

Noise Level : Low

Configuration : BackMounted, Single Cylinder

Motor : N/A (No motor used)

Dimensions : Standard (Adjustable harness fits most sizes)

Air Discharge : Demand Valve (positive pressure)

Vertical Air Receiver Tank

Vertical Air Receiver Tank

Condition : New

Noise Level : Silent operation (no moving parts)

Configuration : Vertical

Dimensions : Custom sizes available (standard height: approx. 2000 mm, diameter: 600900 mm)

Air Discharge : Bottom and Side flanged outlet available



Back to top