MEDICAL Zonal Valve Box
MEDICAL Zonal Valve Box

MEDICAL Zonal Valve Box

MEDICAL Zonal Valve Box Specification

  • Material
  • Powder Coated Steel Cabinet, Brass Valve, Polycarbonate Front Panel
  • Technique
  • Modular Construction
  • Connection
  • Threaded
  • Shape
  • Rectangular
  • Head Code
  • Round
  • Type
  • Zonal Valve Box
  • Port Size
  • 1/2 inch to 2 inch
  • Style
  • Wall Mounted
  • Pressure
  • Up to 16 bar
  • Application
  • Medical Gas Pipeline Systems
  • Operating Temperature
  • -10°C to 60°C
  • Indicators
  • Color-coded Gas Identification Labels
  • Alarm Provision
  • Provision for Local and Remote Alarm Integration
  • Compliance
  • Meets HTM 02-01, NFPA 99, and ISO Standards
  • Serviceability
  • Front Service Access for Maintenance
  • Inspection Window
  • Provided for Valve Display
  • Finish
  • Anti-bacterial Powder Coating
  • Front Panel
  • Clear Polycarbonate, Lockable
  • Number of Valves
  • 1 to 6 (customizable)
  • Mounting
  • Surface or Flush Mounted
  • Isolation Valves
  • Quarter Turn Ball Valves
 
 

About MEDICAL Zonal Valve Box

Color Grey
Corrosion Resistance Yes
Display Type Yes
Brand Mediline
Country of Origin Made in India
Material Mild Steel
Packaging Type Box

Our clients can avail from us Zonal Valve Box, which helps in easy storage. Manufactured using superior quality raw material, these products are durable.

Zonal Valve Box:

  • The Zonal Valve Box are fully designed to suit multiple operational requirement and ensure considering space for mounting.
  • The cofigurations of Valve Boxes are described
  • 4 services - O2, N2O, Air, Vacuum (15, 15, 15, 22 mm)
  • 3 services - O2, Air, Vacuum (15, 15, 22 mm)
  • 2 services - O2, Vacuum (15, 22 mm)


Customizable Valve Configuration

Choose between 1 to 6 isolation valves, adjusting to the specific requirements of your medical gas pipeline system. Each valve is clearly displayed through the inspection window, ensuring ease of identification and usage.


Robust and Hygienic Construction

Built using powder-coated steel and a clear polycarbonate panel, the unit offers exceptional durability and anti-bacterial properties. Its modular design supports various mounting styles, making it suitable for diverse healthcare environments.


Compliance and Safety

Designed to meet HTM 02-01, NFPA 99, and ISO standards, the valve box incorporates color-coded indicators and alarm integration. This ensures adherence to global safety regulations and reduces the risk of gas misidentification.

FAQ's of MEDICAL Zonal Valve Box:


Q: How is the Medical Zonal Valve Box installed in healthcare facilities?

A: The valve box can be surface or flush mounted onto the wall, allowing integration into both new and existing medical gas pipeline systems. Threaded connections ensure secure fitting of inlet and outlet ports.

Q: What is the process for servicing or maintaining the zonal valve box?

A: All servicing is performed from the front of the panel, which is lockable for security. The clear polycarbonate panel and inspection window allow visual checks and maintenance without disrupting the system, ensuring minimal operational downtime.

Q: When should the isolation valves be operated within a medical gas pipeline?

A: Isolation valves are typically operated during maintenance, emergency situations, or scheduled inspections. Their quarter-turn design provides quick shut-off for individual gas zones, increasing safety and control.

Q: Where are the color-coded gas identification labels located, and what is their benefit?

A: Labels are placed on the front panel and near each valve, using distinct colors for each medical gas. This prevents accidental mix-ups and facilitates fast, accurate identification during emergencies or routine use.

Q: What advantage does alarm integration offer for the zonal valve box?

A: Provision for local and remote alarm systems enables real-time monitoring and immediate response to gas flow changes, leaks, or shutdowns, significantly enhancing facility safety and compliance.

Q: How does modular construction benefit the Medical Zonal Valve Box?

A: Modular construction allows customization in terms of the number of valves and port sizes. It supports easy expansion, repair, and adaptation to changing facility requirements over time.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Zonal Valve Box Category

Zonal Valve Box

Zonal Valve Box

Material : Other, Stainless Steel and Polycarbonate

Application : Medical Gas Pipeline Systems

Style : Wall Mounted

Shape : Other, Rectangular

Port Size : 1/2 inch to 2 inch

Head Code : Square

Medical Zonal Valve Box

Medical Zonal Valve Box

Material : Other, Stainless Steel & Polycarbonate Panel

Application : Medical Gas Piping Systems

Style : Wall Mounted

Shape : Other, Rectangular

Port Size : 1/2 inch to 2 inch

Head Code : Other, Standard

Zonal Valve Box

Zonal Valve Box

Material : Stainless Steel

Application : Hospital



Back to top