Lightweight Self Contained Open Circuit Breathing Apparatus
Lightweight Self Contained Open Circuit Breathing Apparatus

Lightweight Self Contained Open Circuit Breathing Apparatus

Lightweight Self Contained Open Circuit Breathing Apparatus Specification

  • Air Discharge
  • Demand Valve (positive pressure)
  • Noise Level
  • Low
  • Condition
  • New
  • Material
  • Flame-retardant Composite, Rubber, Polycarbonate Face Mask
  • Power Source
  • Compressed Air
  • Dimensions
  • Standard (Adjustable harness fits most sizes)
  • Configuration
  • Back-Mounted, Single Cylinder
  • Mute
  • Yes
  • Air Flow Capacity
  • 40 L/min
  • Driven Method
  • Compressed Air Cylinder
  • Working Presssure
  • 200-300 bar
  • Motor
  • N/A (No motor used)
  • Harness Type
  • Adjustable, Padded Shoulder Straps
  • Colour
  • Black/Yellow (as per model)
  • Cylinder Material
  • Aluminum Alloy or Composite
  • Weight
  • Lightweight (Approx. 8-10 kg with cylinder)
  • Face Mask Type
  • Full Face, Anti-fog Visor
  • Visibility
  • Wide Field of Vision
  • Warning Signal
  • Low Pressure Audible Alarm
  • Regulator Type
  • First Stage and Demand Valve
  • Temperature Range
  • -30°C to +60°C
  • Duration
  • Up to 60 Minutes (depending on usage and cylinder size)
  • Application
  • Firefighting, Rescue, Industrial Safety
  • Cylinder Capacity
  • 6.8 Litre
 
 

About Lightweight Self Contained Open Circuit Breathing Apparatus

Usage/Application Hospital
Brand Mediline
Audio Alarm System 8 Minutes
Duration of Working 30 Minutes
Capacity of Cylinder 800 L
Body Material SS
Country of Origin Made in India

Engaged in offering range of Self Contained Open Circuit Breathing Apparatus. Known for their high durability these Breathing Apparatus are majorly used in emergencies. We offer these at competitive market rates.


Comprehensive Respiratory Protection

Engineered to withstand the toughest work conditions, this breathing apparatus offers complete respiratory protection for firefighters, emergency responders, and industrial personnel. Its lightweight build and comfortable harness design minimize fatigue, while its robust performance ensures users are shielded from hazardous atmospheres.


High-Performance Features

The device is equipped with a 6.8-litre capacity cylinder made of durable aluminum alloy or composite materials. Supporting up to 60 minutes of breathing time, the apparatus includes positive pressure demand valves, a low pressure warning alarm, and a wide, anti-fog visor that enhances visibility and operational safety.


Designed for User Comfort and Safety

The adjustable harness with padded shoulder straps offers customized comfort, accommodating various body sizes for secure wear. Its flame-retardant composite construction, minimal noise operation, and positive pressure air discharge make it suitable for long-duration use in hazardous environments.

FAQ's of Lightweight Self Contained Open Circuit Breathing Apparatus:


Q: How does the lightweight self-contained open circuit breathing apparatus work?

A: This breathing apparatus delivers breathable compressed air from an onboard cylinder through a first stage and a demand valve regulator. The positive-pressure system ensures that only air from the cylinder reaches the user, protecting against contaminated atmospheres during firefighting, rescue, or industrial operations.

Q: What benefits does the full-face anti-fog visor provide?

A: The full-face, anti-fog visor enhances visibility by preventing condensation and offering a wide field of vision. This feature is crucial for maintaining situational awareness and safety in environments filled with smoke, dust, or chemical vapors.

Q: When should I use this breathing apparatus?

A: This apparatus is ideal for situations where the ambient air is potentially hazardous, such as firefighting, confined space rescue, or industrial safety operations involving chemicals or low oxygen environments. It should be worn whenever respiratory protection is mandated.

Q: Where can this breathing apparatus be typically deployed?

A: It is primarily designed for use in fire departments, emergency response teams, industrial facilities, and situations where airborne toxins or reduced oxygen levels are present, making it indispensable for occupational safety in India and globally.

Q: What is the process for donning and using the apparatus?

A: Begin by inspecting the apparatus for integrity and pressure. Position the back-mounted cylinder and secure the adjustable padded harness. Fit the full-face mask snugly, check the seal, open the cylinder valve, and confirm audible alarm function. Breathe normally; the demand valve provides air as needed.

Q: How does the low-pressure audible alarm function help in safety?

A: The low-pressure audible alarm is a critical safety feature that alerts the user when air supply drops to a preset level. This signal allows users to exit hazardous areas safely before their air supply is fully depleted.

Q: What advantages does the lightweight design offer during long operations?

A: Weighing approximately 8-10 kg (including the cylinder), the lightweight design minimizes user fatigue and maximizes mobility, allowing for extended and more comfortable use during emergency or industrial tasks.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Plant Medical Air Vacuum System Category

Indo Air Compressor

Indo Air Compressor

Material : Cast Iron

Motor : 5 HP Electric Motor

Condition : New

Voltage : 415 V

Power Source : Electric

Air Flow Capacity : 15.7 CFM

Medical Air and Gas Filter For Hospital

Medical Air and Gas Filter For Hospital

Material : MedicalGrade Polymer and Stainless Steel

Motor : Electric Motor, HighEfficiency Type

Condition : New

Voltage : 220V / 50Hz

Power Source : AC Powered

Air Flow Capacity : 40300 L/min

Two Stage Indo Air Compressor

Two Stage Indo Air Compressor

Material : Cast Iron

Motor : 3 HP

Condition : New

Voltage : 415 V

Power Source : Electric

Air Flow Capacity : 285 LPM

Light Weight and Portable Mediline Oxygen Kit

Light Weight and Portable Mediline Oxygen Kit

Material : Stainless Steel & Medical Grade Plastic

Motor : Brushless DC

Condition : New

Voltage : 220V AC (for concentrator) / Not required for cylinder

Power Source : Electric / Cylinder

Air Flow Capacity : 510 LPM